Maintenance Instructions - Regency PG33-NG Owners & Installation

Table of Contents

Advertisement

WARNING: CHILDREN AND
ADULTS SHOULD BE ALERTED
TO THE HAZARDS OF HIGH
SURFACE TEMPERATURE AND
SHOULD STAY AWAY TO AVOID
BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE
CAREFULLY SUPERVISED WHEN
THEY ARE IN THE SAME ROOM AS
THE APPLIANCE.
CLOTHING OR OTHER FLAM-
MABLE MATERIAL SHOULD NOT
BE PLACED ON OR NEAR THE
APPLIANCE.
DO NOT USE THIS APPLIANCE
IF ANY PART HAS BEEN UNDER
WATER. IMMEDIATELY CALL AN
AUTHORIZED SERVICE TECHNI-
CIAN TO INSPECT THE APPLI-
ANCE AND TO REPLACE ANY
PART OF CONTROL SYSTEM AND
ANY GAS CONTROL WHICH HAS
BEEN UNDER WATER.
CAUTION: ANY SAFETY SCREEN
OR GUARD REMOVED FOR SERV-
ICING AN APPLIANCE MUST BE
REPLACED PRIOR TO OPERAT-
ING THE APPLIANCE.
Regency PG33 Gas Inbuilt
MAINTENANCE
INSTRUCTIONS
Any maintenance required accessing the
glass door of the unit must be performed
by an authorized service person.
1) Always unplug the power cord before
cleaning. For relighting, refer to lighting
instructions. Keep the burner and control
compartment clean by brushing and vacu-
uming at least once a year. When cleaning
the logs, use a soft clean brush as the logs
are fragile and easily damaged.
2) Clean glass (never when unit is hot), appli-
ance, louvres, and door with a damp cloth.
Never use an abrasive cleaner. The gold
louvres (and optional gold door) may be
scratched if abrasives are used to clean
them.
The heater is finished in a heat resistant
paint and should only be refinished with
heat resistant paint (not with wall paint).
Regency uses StoveBright Paint - Metallic
Black #6309.
3) Make a periodic check of burner for proper
position and condition. Visually check the
flame of the burner periodically, making sure
the flames are steady; not lifting or floating. If
there is a problem, call an authorized service
person.
4) The appliance and flueing system must be
inspected before use, and at least annu-
ally, by an authorized field service person,
to ensure that the flow of combustion and
ventilation air is not obstructed.
During the annual service call, the burners
should be removed from the burner tray and
cleaned. Replace the embers - do not block
the pilot or burner ports.
5) Keep the area near the appliance clear and
free from combustible materials, gasoline
and other flammable vapours and liquids
6) Verify proper operation after servicing.
.
MAINTENANCE
General Flue Maintenance
Conduct an inspection of the flueing system semi-
annually. Recommended areas to inspect as follows:
1) Check the Flueing System for corrosion in areas
that are exposed to the elements. These will
appear as rust spots or streaks, and in extreme
cases, holes. These components should be
replaced immediately.
2) Remove the Cap, and shine a flashlight down
the Flue. Remove any bird nests, or other foreign
material.
3) Check for evidences of excessive condensation,
such as water droplets forming
in the inner liner, and subsequently dripping out
the joints, Continuous condensation can cause
corrosion of caps, pipe, and fittings. It may be
caused by having excessive lateral runs, too
many elbows, and exterior portions of the system
being exposed to cold weather.
4) Inspect joints, to verify that no pipe sections or
fittings have been disturbed, and consequently
loosened. Also check mechanical supports such
as Wall Straps, or plumbers' tape for rigidity.
5) Reverse the previous steps, replace the glass
clips and fasten with the nuts but do not over
tighten, as this can break the glass.
6) Replace door on the stove and check the seal.
33