Removing Valve Tray - Regency PG33-NG Owners & Installation

Table of Contents

Advertisement

MAINTENANCE
1) Shut off the gas supply.
2) Remove the louvres.
3) Open the flush door and remove door.
4) Remove the logs.
5) Remove the burner/grate assembly by removing the 2 Philips head
screws and then lift the burner assembly out.
Remove the left and right screws and then lift
out the burner/grate assembly.
6) Remove the rear log log stand by removing the 2 screws.
Rear Log Stand
7) Disconnect the inlet gas line.
36

REMOVING VALVE TRAY

8) Remove the 10 Philips screws which secure the valve tray assembly.
9) Unplug the 2 orange wires from the Gas Pressure Electric Modulator.
10) Unplug the 5 pin Molex Connector from the valve.
11) Unplug the ignitor and flame cables from the module and then lift the
entire valve tray assembly out.
12) To replace the burner tray assembly reverse these instructions.
13) Check for any gas leaks.
14) Check for proper flame appearance and glow on logs.
Flame
Cable
2 Orange
5 Pin Molex
Wires
Connector
Valve Tray Assembly
Regency PG33 Gas Inbuilt
Ignitor
Cable
Module