Installation Checklist; Locating Your Gas Stove - Regency PG33-NG Owners & Installation

Table of Contents

Advertisement

INSTALLATION
INSTALLATION
CHECKLIST
1) Locate appliance
a) Room location, page 6
b) Clearances to Combustibles, page 7
c) Mantle Clearances, page 7
d) Framing & Finishing Requirements,
page 8
e) Flueing Requirements, pages 10 to 15.
2) Assemble Top Facing Support and Side
Nailing Strips, page 9. (NOTE: must be done
before installing unit into fireplace.)
3) Install flue, pages 10 to 25.
4) Make gas and electrical connections. Test
the pilot. Must be as per diagram. Page 26.
Convert to LPG if desired, page 27.
5) Install brick panels (optional), page 33.
6) Install logs and embers and rockwool where
indicated on page 33.
7) Install Flush Door Front (Standard) and
optional Flush Gold Trim, page 35.
8) Install optional Double Screen Door, page
36.
9) Install Louvers
10) Final check.
Before leaving this unit with the customer, the
installer must ensure that the appliance is fir-
ing correctly and operation fully explained
to customer.
This includes:
1) Clocking the appliance to ensure the correct
firing rate (rate noted on label) after burning
appliance for 15 minutes.
2) If required, adjusting the primary air to ensure
that the flame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.
LOCATING YOUR
GAS STOVE
6
23"(584mm)
33"(838mm)
33"(838mm)
12-3/4"(324mm)
1) When selecting a location for your stove,
ensure that the clearances outlined on this
page are met.
2) Provide adequate clearances for servicing.
3) The appliance must be installed on a flat,
solid, continuous surface (e.g. wood, metal,
concrete). This may be the floor, or raised up
on a platform to enhance its visual impact.
If the appliance is going to be installed on
carpeting, combustible linoleum tile or other
combustible material other than wood floor-
ing, the appliance must be installed on a
metal or wood panel extending the full width
and depth of the appliance.
4) The PG33 can be installed in a recessed
position or framed out into the room as in
A, B, C, D. See Diagram 1.
5) This appliance is Listed for bedroom instal-
lations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) The PG33 Direct Flue Gas Fireplace is ap-
proved for alcove installations, which meet
the clearances listed on this page.
7) We recommend that you plan your instal-
lation on paper using exact measurements
for clearances and floor protection before
actually installing this appliance. Have a
qualified inspector, dealer, or installer review
your plans before installation.
Note: For flue terminations see page 10.
A)
Flat on Wall
B)
Flat on Wall Corner
C)
Recessed into Wall/Alcove
D)
Corner
Diagram 1
Regency PG33 Gas Inbuilt