HP 9304m Installation And Getting Started Manual page 47

Procurve routing switches
Table of Contents

Advertisement

Installation and Getting Started Guide
1000BaseLX ports come equipped with SC connectors.
1000BaseT ports come equipped with RJ-45 connectors.
Figure 2.9
Pin assignment and signalling for 10/100BaseTX and 1000BaseT ports
Pin Assignment
8
1
Cable Length
1000BaseT: Cable length should not exceed 100 meters.
100BaseTX: Cable length should not exceed 100 meters.
100BaseFX: Cable length should not exceed 2 kilometers.
1000BaseSX: Cable length should not exceed 550 meters when operating with multi-mode cabling.
1000BaseLX:
Cable length of 2 – 440 meters is supported on 62.5 µm multi-mode fiber (MMF) cabling.
Cable length of 2 – 550 meters is supported on 50 µm multi-mode fiber (MMF) cabling.
Cable length of 2 – 5000 meters is supported on 9 µm single-mode fiber (SMF) cabling.
1000BaseSX
1000BaseLX
2 - 20
10BaseT
Pin Number
MDI-X ports
1
RD+
2
RD-
3
TD
1
4
Not used
5
Not used
6
TD-
8
7
Not used
8
Not used
Table 2.2: Cable length summary table
Fiber Type
Core
Diameter
(microns)
MMF
62.5
MMF
62.5
MMF
50
MMF
50
MMF
62.5
MMF
50
MMF
50
SMF
9
100BaseTX and 1000BaseT
Pin Number
MDI-X ports
1
RD+
2
RD-
3
TD
4
CMT
5
CMT
6
TD-
7
CMT
8
CMT
Modal
Minimum
Bandwidth
Range
(MHz*km)
(meters)
160
a
2 – 200
200
b
2 – 275
400
2 – 500
500
c
2 – 550
500
2 – 550
400
2 – 550
500
2 – 550
n/a
2 – 5000

Advertisement

Table of Contents
loading

This manual is also suitable for:

9315m

Table of Contents