Olivetti d-Color MF2001 Service Manual page 60

Hide thumbs Also See for d-Color MF2001:
Table of Contents

Advertisement

Item No.
5. Change the setting value using the cursor left/right keys or numeric keys.
U034
For output example 1, increase the value. For output example 2, decrease the value.
Leading edge
registration
(20 ± 1.5 mm)
6. Press the start key. The value is set.
Remark
Changing the larger sizes settings affects those for the smaller sizes.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following
adjustments in maintenance mode.
U034
Adjustment: Center line adjustment
1. Press the system menu key.
2. Press the start key to output a test pattern.
3. Press the system menu key.
4. Select the item to be adjusted.
Display
MPT
Cassette1
Cassette2
Cassette3
Duplex
Service Manual
Description
Correct image
Figure 1-3-2
U066
U071
( P.1-3-31)
( P.1-3-36)
Description
Paper feed from MP tray
Paper feed from cassette 1
Paper feed from optional
cassette 2
Paper feed from optional
cassette 3
Duplex mode (second)
1-3-22
Output
Output
example 1
example 2
Setting
range
-128 to 127 0
-128 to 127 0
-128 to 127 0
-128 to 127 0
-128 to 127 0
2KZ/2K0
Initial
Change in
setting
value per step
0.1 mm
0.1 mm
0.1 mm
0.1 mm
0.1 mm
Y113010-4