Item No.
Setting: [Bias Target/Gamma Target]
U464
1. Select the item to be set.
2. Change the setting value using the +/- or numeric keys.
1st
2nd
3rd
4th
3. Press the start key. The value is set.
Method: [Calib]
1. Select the item to be set
2. Press the start key. The operation starts.
Regist
Gamma
Paper Int
Color Regist
To stop operation, press the stop key.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Service Manual
Display
Setting of target (Yellow)
Setting of target (Cyan)
Setting of target (Magenta)
Setting of target (Black)
Display
Executes the calibration to correct registration.
Executes the calibration to quantities of light.
Executes the calibration between paper.
Executes the calibration to color registration.
Description
Description
Description
1-3-84
Setting
Initial set-
range
ting
10 to 1000
935/400
10 to 1000
895/200
10 to 1000
885/200
10 to 1000
846/130
Y113010-4