Item
Section
No.
High voltage
U100
U101
U106
U107
U108
U111
U118
U127
Developer
U135
U136
U139
U140
U147
U150
U157
Y113010-4
Content of maintenance item
Setting the main high voltage
Setting the voltage for the primary transfer
Setting the voltage for the secondary transfer
Setting the voltage for the intermediate transfer cleaning
Setting separation shift bias
Checking the drum drive time
Displaying the drum history
Checking/clearing the transfer count
Checking toner motor operation
Setting toner near end detection
Displaying the temperature and humidity outside the
machine
Setting developer bias
Setting for toner applying operation
Checking sensors for toner
Checking the developing drive time
1-3-3
2KZ/2K0
Initial
setting
145/145/145/145
55/35
0/15/5/20
-3/-3/-3/-3
10
60/60/45/40
80/82/55/40
53/55/41/35
47/52/39/32
45/48/38/30
43/45/35/27
35/45/35/35/25/30
55/45/40/65/55/38
50/41/32/50/40/30
40/38/27/37/36/25
-
-
-
-
-
-
0/0
-
450/150/36/27/1400
480/180/36/27/1400
480/180/36/27/1400
450/150/36/27/1400
50/150/36/27/1000
50/150/36/27/1000
50/150/36/27/1000
50/150/36/27/1000
350/180/36/27/1200
350/180/36/27/1200
350/180/36/27/1200
350/180/36/27/1200
0/0
0/0
0/0
0/0
0/60
-
0/0/0/0
Sevice Manual