5. Remove four FFCs from the operatioon
panel PWB main.
6. Remove four screws and then remove
the operation panel PWB main.
7. Check or replace the operation panel
PWB main and refit all the removed
parts.
Service Manual
Operation panel
PWB main
Screw
Screw
Figure 1-5-62
1-5-34
FFCs
Screw
Screw
2KZ/2K0