Converting From 3" & 3" Venting To 3" & 2; Vent Restrictor Position - Regency L234-NG10 Owners & Installation Manual

Gas insert
Hide thumbs Also See for L234-NG10:
Table of Contents

Advertisement

installation
|
12
CONVERTING FROM 3" & 3" VENTING TO 3" & 2"
1) Remove the top plate from the unit by undoing the screw at the front
of the firebox and slide out towards the back of the unit.
2) Remove the 3" collar from the top plate by undoing the 4 screws.
NOTE: The screws are secured from the underside of the top plate.
Underside of Top Plate
3) Secure the 2" collar to the top plate using 4 screws in place of the 3"
collar.
4) Re-install the top plate to the unit.
Top Plate with 2" Collar shown on Unit
12 |
Regency
L234-10 Direct Vent Gas Insert
®

VENT RESTRICTOR POSITION

The Vent Restrictor plate is located on the inside top of the firebox.
To change the vent restrictor position, refer to the instructions below;
1) Remove the glass door.
2) Remove brick panels if installed.
3) Remove the 4 screws that hold the vent restrictor plate in place.
4) Adjust the vent restrictor plate to the required vent restrictor
position.
1"
Factory Set at 1"
5) Once the vent restrictor plate is in the required position, secure using
the 4 screws removed from step 3.
6) Re-install brick panels if removed.
7) Re-install glass door.
3/4"
Adjusted to 3/4"

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L234-lp10

Table of Contents