installation
|
8

IMPORTANT MESSAGE

SAVE THESE
INSTRUCTIONS
The Regency Direct Vent Gas Insert must be
installed in accordance with these instructions.
Carefully read all the instructions in this manual
first. Consult the building authority having jurisdiction
to determine the need for a permit prior to starting
the installation.
NOTE: Failure to follow the instructions could cause
a malfunction of the heater which could result in
death, serious bodily injury, and/or property damage.
Failure to follow these instructions may also void
your fire insurance and/or warranty.
GAS PRESSURE
TESTING
The appliance must be isolated from the gas supply
piping system by closing its individual manual shut off
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than
1/2 psig. (3.45 kPa).

SPECIFICATIONS

At pressures over 1/2 psig, the pipe to the unit must
be disconnected.
Gas Input Capacity:
Natural Gas 23,500 Btu/h
Propane
21,500 Btu/h
Min. Input:
Natural Gas 12,500 Btu/h
Propane
11,000 Btu/h
Fuels: Approved for use with both natural gas,
and propane. Approved as is for use at 0' to 4,500'
(0-1370m).
Electrical:
120V A.C. system.
Circulation Fan: Variable speed, 127 CFM.
Log Set:
Ceramic fibre, 6 per set.
Vent System:
3" co-linear aluminum flex
or 2" intake with 3" exhaust.
INSTALLATION INTO A SOLID FUEL
BURNING FIREPLACE OR FACTORY
BUILT
FIREPLACE
The L234 Gas Inserts have been tested and
approved to be vented into any masonry fireplace or
approved solid fuel burning factory built fireplace that
will allow the insert to physically fit into the firebox.
Refer to the "Minimum Fireplace Opening" section.
8
|
Regency
L234-10 Direct Vent Gas Insert
®
If the factory built fireplace* height is too low
for your Insert, you may remove the smoke
baffle plate and damper from the factory built
fireplace as long as these items are saved and
are reinstalled in the event that the Insert is
removed. NOTE: Any alterations made to the
listed solid fuel burning factory built fireplace
may void the listing of the fireplace. Cutting
any sheet-metal parts of the fireplace, in which
the gas fireplace insert is to be installed, is
prohibited.
If the factory-built fireplace has no gas
access hole(s) provided, an access hole of
1.5" (37.5mm) or less may be drilled through
the lower sides or bottom of the firebox in a
proper workmanship like manner. This access
hole must be plugged with non-combustible
insulation after the gas supply line has been
installed.
The fireplace and fireplace chimney must
be clean and in good working order and
constructed of non-combustible materials and
chimney cleanouts must fit properly. Refractory,
glass doors, screen rails, screen mesh, and
log grates can be removed from the fireplace
before installing the gas fireplace insert. Smoke
shelves, shields and baffles may be removed if
attached by mechanical fasteners. A tight seal
between the gas fireplace insert flue collar and
the fireplace chimney must be made to prevent
heat loss.
*Check with your local inspector before commencing
with this installation.

BEFORE YOU START

Safe installation and operation of this appliance
requires common sense, however, we are required
by the Canadian Safety Standards and ANSI
Standards to make you aware of the following:
General Safety Information
1) The appliance installation must conform
with local codes or in the absence of local
codes, with CAN/CSA B149.1 (in Canada)
or the National Fuel Gas Code ANSI Z223.1
NFPA 54 in the U.S.A. This appliance should
be installed by a qualified gas fitter technician
only.
2) Installation and repair should be done by a
qualified service person.
3) The appliance should be inspected before
use and at least annually by a professional
service person. More frequent cleaning
may be required due to excessive lint from
carpeting, bedding material, animal hair, etc.
It is imperative that control compartments,
burners and circulating air passageways of
the appliance be kept clean.
4) See general construction and assembly
instructions. This appliance may only be
installed in a vented, noncombustible fireplace.
5) This appliance is Listed for bedroom installations
when used with a Listed Millivolt Thermostat.
Some areas may have further requirements,
check local codes before installation.
6) Always connect this appliance to a vent system
vent that is run (or routed) to the outside of the
building envelope. Never vent to another room
or inside a building. Make sure that the vent
is properly sized and is of adequate height to
provide the proper draft.
7) Inspect the venting system annually for blockage
and any signs of deterioration.
8) Any glass removed for servicing must be
replaced prior to operating the appliance.
9) WARNING: Failure to position the parts in
accordance with the diagrams in this manual
or failure to use only parts specifically
approved with this appliance may result in
property damage or personal injury.
10) To prevent injury, do not allow anyone who is
unfamiliar with the operation to use the fireplace.
Installer must mechanically attach the supplied
label to the inside of the firebox of the fireplace
into which the gas fireplace insert is installed.
"WARNING: This fireplace has been
converted for use with a gas fireplace insert
only and cannot be used for burning wood or
solid fuels unless all original parts have been
replaced, and the fireplace re-approved by
the authority having jurisdiction."