Summary of Contents for Regency MANSFIELD L850B ST
Page 1
Owners & Installation SEE-THRU WOOD FIREPLACE Model: MANSFIELD L850B ST PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult an authorised installer, service agency or the distributor.
Page 2
The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those REGENCY FIRES burning.
Maintenance ..............25 Glass Maintenance ............25 Door Latch Adjustment ..........25 Operating Instructions ..........26 Air slide Control ............26 Wood storage ..............26 Lighting the appliance and the first few fires ....27 Trouble shooting ............28 Main Assembly ............29 Warranty ..............32 Mansfield L850B ST Woodfire...
NOTE: Regency units are constantly being This is a copy of the data badge that accompanies improved. Check the data badge on the unit each L850B ST Fireplace. We have included a copy and if there is a difference, the data badge on of the contents here for your review.
Regency Fireplaces are constructed with the highest quality materials and assembled under strict quality control procedures that ensure years of trouble free and reliable performance. It is important that you read this manual thoroughly and fully understand the safe installation and operating procedures. The more you understand the way your Regency Fireplace operates, the more enjoyment you will experience from knowing that your unit is operating at peak performance.
RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH AC- TION IS CONSIDERED, THE MANUFACTURER SHOULD BE 7) Your Regency heater can be very hot. You may be seriously burned CONSULTED IN THE FIRST INSTANCE. if you touch the heater while it is operating, keep children, clothing and furniture away.
The flue must be of the triple skin type are available, using 150mm ducting to with an approved cowl and must extend The outside dimensions of the Mansfield L850B ST including the Zero a max run of 9 Meters. a minimum of 4.6 metres above the top Clearance Box is as follows: of the floor protector.
OF 8000mm2 WHEN PASSING MINIMUM OF THRU COMBUSTIBLE 1080mm CEILING. ABOVE FUEL LOADING DOOR ON ONE SIDE ONLY LOWER VENTILATION 9mm HEARTH THICKNESS GRILL REQUIRED MINIMUM OPEN EXTENDING 300MM AREA OF 8000mm2 ON ONE SIDE ONLY Mansfield L850B ST Woodfire...
3. Non-combustible board and steel framing is required for the entire enclosure however the ceiling may be of combustible material - see page 9 for minimum ceiling height. 4. Clearances to combustibles for triple skin flue as it passes through ceiling, living spaces = 50mm. 5. Non-combustible with walls of enclosure to be 9mm thick minimum. Mansfield L850B ST Woodfire...
2. ENSURE THE CENTRE OF THE BASE IS HOLLOW TO ALLOW THE HOOK-UP OF THE OPTIONAL OUTSIDE AIR KIT. 3. ENSURE THE BASE IS CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS 4. ENSURE THE BASE CAN WITHSTAND THE WEIGHT OF AT LEAST 332KG PLUS. 5. ENSURE THE FLOOR BENEATH THE BASE CAN WITHSTAND AT LEAST 332KG PLUS. Mansfield L850B ST Woodfire...
11” outside shell – Note: crimped end of outer flue faces upwards. NOTE: INSTALL REGENCY APPROVED FLUE KIT ONLY 4. 9” & 11” galvanized flue skin fitted with aircooling bracket 1. 7" starter flue fitted. Note the crimped end is down (into unit) 5.
Page 13
At this stage of the installation the unit is installed with the flue system and any optional kits. The next step is to install and set the nailing flanges in the correct position to accommodate the front wall framing and finishing. Mansfield L850B ST Woodfire...
FLUE REQUIREMENTS THE FLUE PIPE SHALL EXTEND NOT LESS THAN 4.6 M ABOVE THE TOP OF THE FLOOR PROTECTOR. NOTE: INSTALLATION MUST BE CARRIED OUT BY A LICENSED INSTALLER IN ACCORDANCE WITH AS/NZS 2918:2001 Mansfield L850B ST Woodfire...
6. If using optional outside air kit please refer to the outside air kit in this manual. The optional air kit adapter must be installed prior to the unit being positioned on to the base frame 7. Install the fireplace on the base frame. Secure unit to the base frame Mansfield L850B ST Woodfire...
We suggest, to avoid errors, that these measurements be taken when the heater is actually installed in its final location. Mansfield L850B ST Woodfire...
Bottom nailing flange- secure to left and right vertical nailing flanges Note: Keep left and right nailing flanges off the floor to allow for adjust ability Smaller Bottom Nailing Flange Mansfield L850B ST Woodfire...
Use only high heat non-combustible board. 5. Install the final layer of finishing material such as tile, slate. Etc. ENSURE ALL ADHESIVES/ GLUES/ ETC ARE HIGH HEAT RESISTANT. ALLOW BONDING AGENTS TO CURE PROPERLY BEFORE FIRING UNIT. Mansfield L850B ST Woodfire...
240V Fan As- Aluminum Flex 4.5m sembly from ceiling Duct Flange- Duct Mounting Plate Minimum 102mm Adapter Round Duct Flange-Stove from fl oor to Oval Angle Bracket Sidewall Grille Junction Box Cable Clamp Wall Adapter Plate 919-751 12.19.16 Mansfield L850B ST Woodfire...
Page 21
Round Air Duct: Attach the 152.4mm round air duct (supplied) to the fireplace collar and run the duct to the fan housing. Attach the round-to-oval adapter to the fan housing and the air duct to the adapter Mansfield L850B ST Woodfire 919-751 12.19.16...
Installation of wiring and switching must be carried out by a qualified electrician Note: When using the supplied On / Off Switch or Dimmer (not supplied) remove the Red wire at the motor terminal or insulate the bare end of the Red wire (this connection is not used). Mansfield L850B ST Woodfire...
View with Cover Plate removed and unit adapter installed. flange to ensure tight seal against exterior of home. Join the flex from the unit adapter to the fresh air hood on the inside of the wall 919-479 12.12.16 Mansfield L850B ST Woodfire...
WARNING: Things to remember in case rope seals, and door glass is imperative for the cor- around the start-up air housing located inside rect operation and longevity of your Regency Wood of a flue fire: the heater box, under the loading door lip.
CAUTION: Never leave unit unattended if door is left open. This procedure is a fireplace in your home, a downdraft may be created by your Regency Heater causing a draft down your flue. If this occurs, slightly open a window for fire start-up only, as unit may overheat if door is left open for too long.
Worn gaskets will change Inspect and replace any worn gaskets the airflow of the fireplace to ensure proper airflow patterns and can allow deposits to within the unit. stick to the glass. Mansfield L850B ST Woodfire...
Air Damper Assembly 1564007 Deflector hood 1560019 Door opening tool 3720301 P10 Glass seal rope(2.3m) 1633600 Secondary air tube 1560110 50mm finishing trim with box* N/S = Not Shown * = optional accessory—not a spare part Mansfield L850B ST Woodfire...
Duct Flange 946-002 Round to Oval Adapter 946-007 Angle Bracket 946-004 Junction Box 946-005-AWT Wall Adapter Plate White 948-357 Adapter Round 946-093F Duct Mounting Plate 946-000 Duct Flange Collar 946-006 Side Grill White 904-687 Connector Clamp Mansfield L850B ST Woodfire...
Page 31
COMMISSIONING CHECKS (TO BE COMPLETED AND SIGNED) Is flue system set up in accordance with AS2918 Smoke and Spillage test completed Use of appliance and operation of controls explained Clearance to combustible materials checked Installers Signature: Print Name: Date: Mansfield L850B ST Woodfire...
FPI Fireplace Products International Ltd. (“the manufacturer”) through its wholly owned subsidiary, Fireplace Products Australia Pty Ltd (for Australia and New Zealand customers) and sold under the Regency® brand of fireplace products (collectively referred to herein as “FPI”), extends this Limited Warranty to the original purchaser of this appliance provided the product remains in the original place of installation.
Page 33
Unit must be installed according to all manufacturers’ instructions as per the manual. All Local and National required codes must be met. The installer is responsible to ensure the unit is operating as designed at the time of installation. Mansfield L850B ST Woodfire Revision Date: December 2016 Regency Wood Products Warranty...
Page 34
Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorisation from FPI may void this warranty. INCORRECT INSTALLATION IS NOT COVERED BY WARRANTY. A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES. Mansfield L850B ST Woodfire...
Page 35
(including negligence), statute or otherwise. (b) Loss means any expense, cost or damage of any kind and includes Consequential Loss and a fine or penalty imposed by a statutory or other authority. Revision Date: December 2016 Regency Wood Products Warranty Mansfield L850B ST Woodfire...
Page 36
Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com.au/Customer-Care/Warranty-Registration.aspx...
Page 37
Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.