ASSEMBLY PROCEDURE

1. Center the gas log unit in the fi replace or fi rebox.
2. Install Grate: Insert longest middle grate bar in one of
the two square holes in control panel. Figure 11. Be sure
grate is centered. Sit horizontal bar inside two hooks
on front of control panel. Figure 11. Make certain front
feet of grate are located inside front edge of fi replace
or fi rebox.
3. Anchor holes are located on the fl ange of the unit. Figure
11. After centering the burner correctly, mark the hole
positions on the fi replace/fi rebox fl oor. Drill two (2) 5/32"
diameter holes approximately 1
4. Anchor the unit to the fi replace/fi rebox fl oor using the
screws provided. Figure 12.
Hole for
Grate Bar
Middle
Grate Bar
Hooks for
Grate
Figure 11 -
Install Grate and Secure Heater to Floor
of Fireplace/Firebox
CONNECT THE GAS LINE
NOTICE: A qualifi ed gas appliance installer must
connect the heater to the gas supply. Consult all local
codes.
12
1
" deep.
2
Screws
Horizontal
Grate Bar
Use new black iron or steel pipe. Internally
tinned copper or copper tubing can be
used per National Fuel Code, section 2.6.3,
providing gas meets hydrogen sulfide
limits, and where permitted by local codes.
Gas piping system must be sized to provide
minimum inlet pressure (Listed on Data
Plate) at the maximum fl ow rate (BTU/Hr).
Undue pressure loss will occur if the pipe
is too small.
A manual shutoff valve must be installed
upstream of the appliance. Union tee
and plugged 1/8" NPT pressure tapping
point should be installed upstream of the
appliance. Figure 12
To
Heater
Valve
Pipe
Coupling
Figure 12 -
Gas Connection
IMPORTANT: Hold heater valve fi rmly with a wrench to
Anchor
prevent movement when connecting to inlet pipe.
Hole
CHECK GAS TYPE: The gas supply must
be the same as stated on the heater's rat-
ing plate. If the gas supply is different, DO
NOT INSTALL THE HEATER. Contact your
dealer for the correct model.
Connecting directly to an unregulated pro-
pane/LPG tank can cause an explosion.
Always use an external regulator for all propane/LPG
heaters and high pressure one to two-pound systems
only, to reduce the supply tank pressure to a maximum of
13" w.c. This is in addition to the internal regulator in the
heater valve.
INSTALLATION
Stainless
Flexible
Tube
Pipe
Manual Shutoff
Valve
Possible Locations
for Pressure
Tapping Point
Gas
Supply
Inlet
FP2371