as they are burned off during the initial operation of the
appliance; possibly causing headaches or eye or lung
irritation. This is a normal and temporary occurrence.
The initial break-in operation should last two to three
hours with the burner at the highest setting. Provide
maximum ventilation by opening windows or doors to
allow odors to dissipate. Any odors remaining after this
initial break-in period will be slight and will disappear
with continued use.
20. Input ratings are shown in BTU per hour and are for
elevations up to 2,000 feet. For elevations above 2,000
feet, input ratings should be reduced 4 percent for each
1,000 feet above sea level. See the National Fuel Gas
Code.
21. The heater and its individual shutoff valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures
in excess of 1/2 psig (3.5 kPa).
22. The heater must be isolated from the gas supply piping
system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psig
(3.5 kPa).
23. Do not use this room heater if any part has been under
water. Immediately call a qualifi ed service technician
to inspect the room heater and to replace any part
of the control system and any gas control which has
been under water.
24. This appliance must not be used with glass doors in
the closed position. This can lead to pilot outages and
severe sooting outside the fi replace.
25. Never burn solid fuels in a fi replace where an unvented
room heater is installed.
26. Always have a fi replace screen in place when the ap-
pliance is in operation and , unless other provisions for
combustion air are provided, the screen shall have an
opening(s) for induction of combustion air.
4
IMPORTANT SAFETY INFORMATION
Never connect unit to private (non-utility)
gas wells. This gas is commonly known
as wellhead gas.
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.

CODES

Adhere to all local codes or, in their absence, the latest
edition of THE NATIONAL FUEL GAS CODE ANSI Z223.1
or NFPA54 which can be obtained from...
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Attention Massachusetts Residents:
This product must be installed by a licensed gas
fi tter.