Millivolt Control Lighting Instructions - Vermont Castings PH24 Appliance Installation And Operating Instructions

Unvented gas log heater/ vented decorative
Table of Contents

Advertisement

OPERATING INSTRUCTIONS

MILLIVOLT CONTROL LIGHTING INSTRUCTIONS

1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo
ignitor does not light the pilot, refer to instructions for Match Lighting Instructions, Page 28.
4. Turn gas control knob clockwise
switch to OFF position.
5. Wait (5) minutes to clear out any gas. Then smell for gas, including near the fl oor. If you smell gas,
STOP! Follow What to Do if You Smell Gas, Page 25. If you don't smell gas, go to next step.
6. From OFF position, turn the gas control knob counterclockwise
knob for 5 seconds. NOTE: If you are running the heater for the fi rst time, it may be necessary to
press in the control knob for 30 seconds orlonger to allow air to bleed out of the gas piping.
7. With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
8. Continue pushing the control knob in for a further 60 seconds to prevent the fl ame detector from shut-
ting off the gas while the probe is warming up. Release the control knob.
9. Turn gas control knob counterclockwise
10. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to ON
position or adjust thermostat to desired setting. NOTE: To use the thermostat function (if installed)
the control knob must be set to "ON" and ON/OFF switch must in the "OFF" position.
11. If the gas logs will not operate, follow the instructions To Turn Off Gas To Heater below and call your
service technician or gas supplier.
FP2275
Pilot
1. Turn control knob clockwise
2. If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
3. If applicable: Turn off all electric power to the heater.
65D2035
to the OFF position, set thermostat to lowest setting and turn ON/OFF
Millivolt Controls
TO TURN OFF GAS TO HEATER
to OFF position to completely shut off the heater.
to the ON position.
Piezo
Hi/Lo Control
Ignitor Pilot
Control
PH Gas Logs
to IGN position. Push in control
ON/OFF
Switch
FP2927
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ph18

Table of Contents