INSTALLATION

BEFORE FULLY INSTALLING THE UNIT:
Turn OFF the gas supply to the fi replace or fi re-
box.
Seal any fresh air vents and/or ash clean-out doors
located on the fl oor or wall of the fi replace. If left
unsealed, drafting may cause pilot outage or soot-
ing. Use a heat resistant sealant. Do not seal the
chimney fl ue damper.
Before installing in a solid fuel burning
fireplace, The chimney flue and firebox
must be cleaned of soot, creosote, ashes
and loose paint by a qualified chimney
cleaner.

INSTALLING VENTED APPLICATIONS

Manual and millivolt controlled gas logs may be installed as
a vented decorative log set in compliance with ANSI Z21.60
and National Fuel Gas Code, Section 6.6 Since, the gas
logs are operated with the damper open, non-combustible
material and minimum mantel requirements do not apply.
This appliance is for installation only in a solid
fuel burning fi replace (masonry fi replace or
manufactured fireplace) with a working
fl ue and constructed of noncombustible
material.
Exception: DO NOT install this appliance
in a factory-built fireplace that includes
instructions stating that it has not been
tested or should not be used with unvented
gas logs. This log set may be installed as a
vented log set.
BEFORE INSTALLING THE APPLIANCE:
Turn off gas supply to fi replace or fi rebox.
Have the fi replace fl oor and chimney professionally
cleaned to remove ashes, soot, creosote or other
obstructions. Have this cleaning performed annually
after installation.
Seal any fresh air vents or ash clean-out doors lo-
cated on fl oor or wall of fi replace. If not, drafting may
cause pilot outage or sooting. Use a heat-resistant
sealant. Do not seal chimney fl ue damper.
Install and operate the appliance as directed in this
manual.
65D2035

DAMPER STOP INSTALLATION:

A damper stop must be provided with the unit. Contact your
dealer to obtain one. The damper stop must be installed as
shown in Figure 10 to prevent full closure of the fi replace
damper blade and provide a minimum 29 square inch fl ue
opening.
Damper
Stop
FP2538
The fi replace and gas logs function as a
system. If the fi replace is spilling into the
room (check with a match or a smoke stick),
reposition the damper clamp until a positive
draft is obtained by opening the damper. If
negative pressure in home prevents having
a positive draft, contact your dealer for
assistance.

PLACE AND SECURE APPLIANCE

You must secure the gas log heater to
the fi replace fl oor. If not, the entire unit
may move when you adjust the controls.
Movement of unit may cause shifting of
the gas logs which leads to sooting and
improper burning.
Special care is required if you are installing
the unit into a sunken fi replace. You must
raise the fi replace fl oor to allow access to
gas log controls. This will insure adequate
air fl ow and guard against sooting. Raise
the fi replace fl oor using noncombustible
materials, as described in Placement in a
Fireplace with Restrictive Barrier on Page
7.
PH Gas Logs
Damper
Figure 10 -
Damper Stop Installation
(See Warning)
11