Assembly and Installation
A. Venting Requirements & Options
Approved Vent System Components
The Intrepid DV Heater must be vented to the outdoors
through an adjacent exterior wall or through the roof. The
venting system must be comprised of the appropriate listed
venting components specified on this page. These parts
are available from DuraVent Corporation or your Vermont
Castings Dealer.
See Figure 2.4 for dimensions relevant to the standard
minimum-vent kits.
HHT Components*
Stove Adapter Kit (Includes 30' of 4" Flex,
adapters, wall thimble, masonry and ZC
flashing, 991DA Cap and Fasteners
Trapezoid Termination Kit (3-1/8" - 4-3/4")
Trapezoid Termination Kit (5-1/4" - 9-1/4")
Rear Vent Termination Kit
Vertical Termination cap – High Wind
(includes storm collar)
Decorative Wall Thimble Cover
Decorative ceiling firestop – black
Cathedral ceiling support – black
4" (100mm) pipe length – black
6" (150mm) pipe length – black
12" Pipe length-black
24" Pipe length-black
36" (915mm) pipe length – black
48" Pipe length-black
3" - 6" (75 – 150mm) telescoping pipe
extension – black
3" - 12" telescoping pipe extension-black
45 degree elbow-black
90 degree elbow-black
SL Snorkel Cap (Includes 1 pair of firestops)
Note: An adapter is not required when using HHT SLP vent pipe on this unit. The twist lock tabs on SLP pipe will not engage
the twist lock of the DuraVent collar. A gas tight seal will still be made between the inner and outer pipe sections. Use a
minimum of two screws to secure the SLP pipe to the starter collar.
1313
LINK-STOVE
SLP-TRAP1
SLP-TRAP2
SLP-RVTK
SLP-TVHW
SLP-WT-BK
SLP-DCF-BK
SLP-CCS-BK
SLP4-BK
SLP6-BK
SLP12-BK
SLP24-BK
SLP36-BK
SLP48-BK
SLP6A-BK
SLP12A-BK
SLP45-BK
SLP90-BK
SLK-SNKD
Vermont Castings • Intrepid DV-IFT Owner's Manual_R20 • 11/21
DuraVent Components
90° Elbow, Blk.
45° Elbow, Gal.
6" Straight, Blk.
9" Straight, Blk.
11" – 14
" Adjustable Straight Section
5 5
8 8
12" Straight
24" Straight
36" Straight
48" Straight
Horizontal Vent Cap
Wall Plate
Vinyl Siding Shield
Snorkel Termination – 14"
Snorkel Termination – 36"
Wall Strap
Cathedral Ceiling Support Box
Storm Collar
Firestop Spacer
Flashing 0/12 - 6/12
Flashing 6/12 - 12/12
Wall Thimble
Wall Thimble Cover (Brass)
Wall Firestop
Attic Installation Shield
Co-Linear Vent Adapter
Steel Chimney Conv. Kit A (6-5/8" - 8-5/8")
Steel Chimney Conv. Kit B (6-5/8" - 10-1/2")
Steel Chimney Conv. Kit C (6-5/8" – 13")
Masonry Chimney Conversion Kit
Vertical Termination Cap (High Wind)
Vertical Termination Cap (Low Profile)
All DuraVent Straight vent pipe sections have a net length 1-1/2"
(37mm) less than the nominal dimension; i.e., a 6" (152 mm)
Straight pipe section has an effective length of 4-1/2" (115 mm).
46DVA-E90B
46DVA-E45
46DVA-06B
46DVA-09B
46DVA-08AB
46DVA-12
46DVA-24B
46DVA-36B
46DVA-48
46DVA-HC
46DVA-DC
46DVA-VSS
46DVA-SNK14
46DVA-SNK30
46DVA-WS
46DVA-CS
46DVA-SC
46DVA-FS
46DVA-F6
46DVA-F12
46DVA-WT
3PVP-TKV
46DVA-WFS
46DVA-IS
46DVA-GCL
46DVA-KCA
46DVA-KCB
46DVA-KCC
46DVA-KMC
46DVA-VCH
46DVA-VC
3-90-30007474

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents