Assembly and Installation
A. Venting Requirements & Options
Approved Vent System Components
The Radiance Heater must be vented to the outdoors through
an adjacent exterior wall or through the roof. The venting
system must be comprised of the appropriate listed venting
components specified on this page. These parts are available
from DuraVent Corporation or your Vermont Castings Dealer.
See Figure 2.4 for dimensions relevant to the standard
minimum-vent kits.
HHT Components*
SLP Horizontal Termination Kit (Termination
Cap, SLP24-BK, SLP6-BK, SLP6A-BK,
SLP90-BK, SLP-WT-BK & CCSLP)
Stove Adapter Kit (Includes 30' of 4" Flex,
adapters, wall thimble, masonry and ZC
flashing, 991DA Cap and Fasteners
Trapezoid Termination Kit (3-1/8" - 4-3/4")
Trapezoid Termination Kit (5-1/4" - 9-1/4")
Rear Vent Termination Kit
Vertical Termination cap - High Wind
(includes storm collar)
Decorative Wall Thimble Cover
Decorative ceiling firestop - black
Cathedral ceiling support - black
4" (100mm) pipe length - black
6" (150mm) pipe length - black
12" Pipe length-black
24" Pipe length-black
36" (915mm) pipe length - black
48" Pipe length-black
3" - 6" (75 - 150mm) telescoping pipe
extension - black
3" - 12" telescoping pipe extension-black
45 degree elbow-black
90 degree elbow-black
Radiance, Stardance, Oxford SLP adapter
Freestanding Draft Hood Adapter
SL Snorkel Cap (Includes 1 pair of firestops)
*CCSLP adapter is required when using HHT components.
1313
SLP-SK-BK
LINK-STOVE
SLP-TRAP1
SLP-TRAP2
SLP-RVTK
SLP-TVHW
SLP-WT-BK
SLP-DCF-BK
SLP-CCS-BK
SLP4-BK
SLP6-BK
SLP12-BK
SLP24-BK
SLP36-BK
SLP48-BK
SLP6A-BK
SLP12A-BK
SLP45-BK
SLP90-BK
CCSLP
FSDHAGSLP
SLK-SNKD
Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19
DuraVent Components
Starter Pipe Assembly (incl. inner & outer
sections)
90° Elbow, Blk.
45° Elbow, Gal.
6" Straight, Blk.
9" Straight, Blk.
11" - 14-5/8" Adjustable Straight Section
12" Straight
24" Straight
36" Straight
48" Straight
Horizontal Vent Cap
Wall Plate
Vinyl Siding Shield
Snorkel Termination - 14"
Snorkel Termination - 36"
Wall Strap
Cathedral Ceiling Support Box
Storm Collar
Firestop Spacer
Flashing 0/12 - 6/12
Flashing 6/12 - 12/12
Wall Thimble
Wall Thimble Cover (Brass)
Wall Firestop
Attic Insulation Shield
Co-Linear Vent Adapter
Steel Chimney Conv. Kit A (6-5/8" - 8-5/8")
Steel Chimney Conv. Kit B (6-5/8" - 10-1/2")
Steel Chimney Conv. Kit C (6-5/8" - 13")
Masonry Chimney Conversion Kit
Vertical Termination Cap (High Wind)
Vertical Termination Cap (Low Profile)
All DuraVent Straight vent pipe sections have a net length
1-1/2" (37mm) less than the nominal dimension; i.e., a 6"
(152 mm) Straight pipe section has an effective length of
4-1/2" (115 mm).
46DVA-ADP
46DVA-E90B*
46DVA-E45
46DVA-06B*
46DVA-09B
46DVA-08AB
46DVA-12
46DVA-24B*
46DVA-36B
46DVA-48
46DVA-HC*
46DVA-DC
46DVA-VSS
46DVA-SNK14
46DVA-SNK30
46DVA-WS
46DVA-CS
46DVA-SC
46DVA-FS
46DVA-F6
46DVA-F12
46DVA-WT
3PVP-TKV
46DVA-WFS
46DVA-IS
46DVA-GCL
46DVA-KCA
46DVA-KCB
46DVA-KCC
46DVA-KMC
46DVA-VCH
46DVA-VC
3-90-30007498