Fujitsu Primergy RX300 S4 User Manual page 70

Hide thumbs Also See for Primergy RX300 S4:
Table of Contents

Advertisement

Chapter 3 OS Installation
4
When a message prompts you to insert the OS CD/DVD, insert the CD/DVD
and click [OK].
For Windows Server 2003 / Windows Server 2003 x64
1. Insert the OS CD/DVD (Installation disc).
The license agreement window appears.
2. Click [I agree].
After files are copied, a message prompts you to eject the CD/DVD and floppy disk.
For Windows Server 2003 R2 / Windows Server 2003 R2 x64
1. Insert the OS CD/DVD (Installation disc) Disc 1.
The license agreement window appears.
2. Click [I agree].
After files are copied, a message prompts you to insert the Disc 2.
3. Insert the Disc 2 of OS CD/DVD (Installation disc).
After files are copied, a message prompts you to eject the CD/DVD and floppy disk.
5
Eject the CD/DVD and floppy disk and click [OK].
The system is restarted. The system continues the installation operation after restart.
Setup of OS GUI and installation of LAN utility, Service Pack, and Active Directory are
performed automatically.
6
When a confirmation message to restart appears, click [Restart].
The system restarts and installs high reliability tools.
7
Press the [Enter] key when a message notifies completion of installation.
8
Restart the system.
Click [Start] – [Shutdown] to restart the system.
After restarting, enter the set password to login.
9
Perform the settings for the RAID management tool (ServerView RAID).
For the setting procedures, refer to the manuals in Array Controller Document & Tool CD.
• Settings of an array administrator account
The Windows user account is required when using ServerView RAID. Create a group named
"raid-adm", and an account with any name for an array administrator within the group "raid-
adm".
• Setting the HDD check scheduler
When using the SAS RAID Ctrl (MegaRAID SAS), change the settings for the HDD check
scheduler according to the operation that is required. It is set to 12:00 everyday as default.
• Configuration of Battery Recalibration Scheduler
When using a SAS RAID Ctrl (MegaRAID SAS) together with a battery backup unit, change
the settings of Battery Recalibration Scheduler according to the operation that is required. The
default setting is 11:00 on the first of every month.
70
Thus the Command Prompt windows may appear and disappear during installation of
ServerView, the installation process is properly proceeding.

Advertisement

Table of Contents
loading

Table of Contents