Installation of an NXD-1700VG

The NXD-1700VG can be installed either directly into the (optional) CB-TP17 or other solid surface environment using the two
different mounting options: drywall clips or solid surface screws. The following sections describe mounting the touch panel directly
into an installed pre-wall Conduit Box, a solid surface or drywall, and optional NXA-RK17 Rack Mount Kit.

Installing the NXD-1700VG within a CB-TP17 Conduit Box

The conduit box must be mounted prior to continuing this section. Refer to the procedures in the Pre-wall Installation of the CB-
TP17 Conduit Box section on page 61 for detailed pre-wall installation instructions. Verify that all necessary cables have been
threaded through the knockouts on the conduit box and the connections have been tested prior to installation of the NXD-1700VG.
1.
Remove the magnetic faceplate/bezel (A in FIG. 56) from the main NXD unit (B in FIG. 56) by gripping the faceplate and pulling
with gentle outward force.
Four #8 flat-head
Mounting Screws
(not included)
secure the NXD to
the Conduit Box
A - Faceplate
(bezel)
Wall Mount panel installation configuration of a CB-TP17 in a pre-wall construction
FIG. 56
2.
Verify the incoming RJ-45, Ethernet, and any other audio/video cables have been properly threaded through the wiring
knockouts on the left of the conduit box. Leave enough slack in the wiring to accommodate any re-positioning of the panel.
3.
Connect all data and power wiring connectors to their corresponding locations along the side of the (un-powered) NXD touch
panel.
Verify the terminal end of the power cable is not connected to a power supply before plugging in the 2-pin power

connector.
The USB connectors can be from either a USB extension cable, or a wireless USB RF transmitter.

4.
Test the incoming wiring by connecting the panel connections to their terminal locations and applying power. Verify the panel
is receiving power and functioning properly to prevent repetition of the installation.
5.
Disconnect the terminal end of the power cable from the connected power supply.
NOTE: Don't disconnect the connectors from the touch panel. The unit must be installed with the attached connectors before
being inserted into the conduit box.
6.
Carefully slide the main NXD unit (B in FIG. 56) into the conduit box, so the Mounting Tab lies flush against the conduit box (C
in FIG. 56).
7.
Insert and secure four securing #8 flat-head Mounting Screws into their corresponding holes located along the sides of the
NXD (FIG. 56). These #8 screws are not included within the CB Installation Kit and must be provided by the installer.
8.
Place the magnetic faceplate (A in FIG. 56) back onto the main NXD unit (B in FIG. 56). Make sure to align the Microphone,
Light, and PIR Motion sensor locations to their respective openings on the front bezel/faceplate.
9.
Reconnect the terminal RJ-45, Ethernet, and any optional audio/video wiring to their respective locations (outside the conduit
box) on either the NXA-AVB/RGB, Ethernet port, or NetLinx Master.
10. Reconnect the terminal power connector on the 12 VDC-compliant power supply and apply power.
Modero VG Series Touch Panels - Instruction Manual
Stud
Support block
Mounting Tab
These are ONLY used to
secure the main unit to the CB
B - Main NXD unit consists of
the touch panel and backbox housing
C - Optional CB-TP17
conduit/wallbox
Do not use these
tabs to mount
the conduit /wallbox
Installation Procedures: 17" Panels