Advertisement

7.
Press the optional Host Name field to open the Keyboard and enter the Host Name information.
8.
Press Done after you are finished assigning the alpha-numeric string of the host name.
9.
Press the Primary DNS field to open a Keyboard, enter the Primary DNS Address (provided by your System Administrator) and
press Done when compete. Repeat this process for the Secondary DNS field.
10. Press the Domain field to open a Keyboard, enter the resolvable domain Address (this is provided by your System Administrator
and equates to a unique Internet name for the panel), and press Done when complete.
11. Navigate to the Master Connection section of this page to begin configuring the communication parameters for the target
Master.

Step 2: Choosing a Master Connection Mode Setting

There are three Ethernet MODE settings used in the Master Connection section of the System Settings page. URL is the most
common method.
Master Connection MODE options:

• URL (Uniform Resource Locator) is the address that defines the route to a file on the Web or any other Internet facility. In this
system, the panel acts as a "Client" and the Master acts as a Server (in that Clients attach to it).
• LISTEN sets the Modero panel to "listen" for broadcasts from the Master (using the panel IP from its URL list). In this system, the
panel acts as a "Server" (in that Clients attach to it) and the Master acts as a "Client".
• AUTO is used to instruct the Modero to search for a Master that uses the same System Number (assigned within the Master
Connection section) and resides on the same Subnet as itself. In this case, the Master has its UDP feature enabled.
This UDP (User Datagram Protocol) is a protocol within the TCP/IP protocol suite that is used in place of TCP when a reliable
delivery is not required. This UDP enabling is done through a Telnet session on the Master. Refer to the particular NetLinx Master
manual for more detailed information.
Step 3: Conf iguring the Ethernet Connection Type
NOTE: When using Ethernet as your communication method, the NetLinx Master must f irst be setup with either a Static IP or DHCP
Address obtained from either NetLinx Studio or your System Administrator.
Before beginning:
1.
Verify the panel has been configured to communicate either through an Ethernet cable (connected from either the panel to a
valid Ethernet Hub) or to a wirelessly to the Wireless Access Point (WAP).
NOTE: Before commencing, verify you are using the latest NetLinx Master f irmware.
2.
Verify that the NetLinx Master is receiving power and is communicating via an Ethernet connection with the PC running
NetLinx Studio.
3.
Connect the terminal end of the 12 VDC-compliant power supply cable to the power connector on the rear/side of the touch
panel.
4.
Verify the green Ethernet LED (from the rear Ethernet port on the Master) is illuminated (indicating a proper connection).
5.
Verify the yellow LED (from the rear Ethernet port on the Master) is blinking (indicating communication).
6.
After the panel powers-up, press and hold the grey Front Setup Access button (for 3 seconds) to proceed to the Setup page.
7.
Select Protected Setup > System Settings (located on the lower-left) to open the System Settings page (FIG. 81).
System Settings page
FIG. 81
Modero VG Series Touch Panels - Instruction Manual
Configuring Communication
Obtained from NetLinx Master
85