Wiring
knockouts
(must be
located on
left side)
Drywall or sheetrock
FIG. 38
CB-TP10 conduit box components
3. Remove the wiring knockouts from the left side of the conduit box (CB-TP10) (FIG. 38) to
accommodate the cables being threaded through to the NXD touch panel.
Remember that when mounting this conduit box, the NXD mounting tabs must lie
flush against the outside of the sheetrock.
4. Thread the incoming power, RJ-45 audio/video, Ethernet, and USB wiring through the knockouts
(use of the left wiring knockouts are recommended with this installation).
Leave enough slack in the wiring to accommodate any re-positioning of the panel.
5. Install the drywall/sheetrock before inserting the main NXD unit into the CB-TP10.

Installation of an NXD Touch Panel

The NXD-CV10 can be installed either directly into the (optional) CB-TP10 or other solid surface
environment using the two different mounting options: drywall clips or solid surface screws. The
following sections describe mounting the touch panel directly into a pre-wall conduit box, a solid surface
or drywall, and optional NXA-RK10 Rack Mount Kit for installation.

Installing the NXD panel within a Conduit Box

The conduit box must be mounted prior to continuing this section. Refer to the procedures in the
Pre-Wall Installation of the Conduit Box section on page 38 for detailed pre-wall installation
instructions. Verify that all necessary cables have been threaded through the knockouts on the left of the
conduit box and the connections have been tested prior to installation of the NXD-CV10.
1. Remove the Faceplate/bezel (A in FIG. 39) from the main NXD unit (B in FIG. 39) by gripping the
faceplate and pulling with gentle outward force.
2. Verify the incoming power, RJ-45 audio/video, Ethernet, and USB cables have been properly
threaded through the wiring knockouts on the left of the conduit box. Leave enough slack in the
wiring to accommodate any re-positioning of the panel.
3. Connect all data and power wiring connectors to their corresponding locations along the side of the
(un-powered) NXD touch panel.