Installation Of The Nxd Touch Panel; Installing The Nxd Panel Within A Conduit Box - AMX NXD-1700VG Instruction Manual

Modero vg series wall/flush mount touch panels
Hide thumbs Also See for NXD-1700VG:
Table of Contents

Advertisement

2.
Remove any necessary wiring knockouts from the (optional) CB-TP12/15 conduit box (C in FIG. 39) where the necessary
cables are threaded through for connection to the touch panel.
3.
Thread the incoming RJ-45, Ethernet, and any other audio/video wiring through the knockouts. Refer to the Wiring Guidelines
for the 1200VG and 1500VG Panels section on page 56 for pinout descriptions. Leave enough slack in the wiring to
accommodate any re-positioning of the panel.
4.
Install the drywall/sheetrock before inserting the main NXD unit into the CB-TP12/15.

Installation of the NXD Touch Panel

The NXD panel can be installed either directly into the (optional) CB-TP12/15 or other solid surface environment using the two
different mounting options: drywall clips or solid surface screws. The following sections describe mounting the touch panel directly
into a pre-wall installed conduit box, a solid surface or drywall, and optional NXA-RK Rack Mount Kit.

Installing the NXD Panel Within a Conduit Box

The conduit box must be mounted prior to continuing this section. Refer to the procedures in the Pre-wall Installation of the Conduit
Boxes section on page 47 for detailed pre-wall installation instructions. Verify that all necessary cables have been threaded through
the knockouts on the conduit box and the connections have been tested prior to installation of the NXD panel.
1.
Remove the magnetic faceplate/bezel (A in FIG. 39) from the main NXD unit (B in FIG. 39) by gripping the faceplate and pulling
with gentle outward force.
Install the four #4-40
screws into the places
A - Faceplate
(bezel)
Wall Mount panel installation configuration for pre-existing conduit/wallbox in a pre-wall construction
FIG. 39
2.
Verify the incoming RJ-45, Ethernet, USB, and any other audio/video cables have been properly threaded through the wiring
knockouts (from their terminal locations) on the conduit box. Leave enough slack in the wiring to accommodate any re-
positioning of the panel.
3.
Connect all data and power wiring connectors to their corresponding locations along the side of the (un-powered) NXD touch
panel.
Verify the terminal end of the power cable is not connected to a power supply before plugging in the 2-pin power

connector.
The USB connectors can be from either a USB extension cable, or a wireless USB RF transmitter.

4.
Test the incoming wiring by connecting the panel connections to their terminal locations and applying power. Verify the panel
is receiving power and functioning properly to prevent repetition of the installation.
5.
Disconnect the terminal end of the power cable from the connected power supply.
NOTE: Don't disconnect the connectors from the touch panel. The unit must be installed with the attached connectors before
being inserted into the conduit box.
6.
Carefully slide the main unit (B in FIG. 39) into the conduit box, so that all Mounting Tabs lie flush against the conduit box (C in
FIG. 39).
Modero VG Series Touch Panels - Instruction Manual
Stud
Cable
knockouts
Mounting Tab
indicated
C - Optional CB-TP
conduit/wallbox
SURFACE
Do not use these
tabs to mount
the conduit /wallbox
These are ONLY used to
secure the main unit to the CB
B - Main NXD unit consists of
the touch panel and backbox housing
Installation Procedures: 12" and 15" Panels
Installed flush
against the
finished wall
surface
48

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nxd-1200vgNxt-1500vgNxt-1700vgNxd-1500vgNxt-1200vg

Table of Contents