The power supplies for the processor and I/O expansion units
provide
five
regulated
DC
output
voltages:
+5.0,
+8.5,
+12.0,
-5.0,
and
-12.0
volts.
Both
supplies
contain
overvoltage,
undervoltage,
and
overcurrent
protection.
Should
overvoltage
or
undervoltage
occur,
the condition
initiates
d
power supply shutdown sequence.
2~~L!!£..!!£.il!,g
.R~gJ!i£~~Ql§.
The
power-on
reset
siqnal
is
provided to assure the state of the logic
during
power
on
and
off.
The
signal is TTL compatible.
Logical one (up)
lev~l
is between +2.6V and 5.5V.
Logical 0 (down)
level
is
between O.OV and +O.4V.
The power-on reset signal starts at
the TTL down
level.
When the +5V, -SV, and +8.5V are within
operational
limits,
this
signal
goes to the TTL up level
after
a 500
millisecond delay.
Should
any
ot
the
three
voltages go approximately J% below their minimum tolerances,
this signal goes to the
TTL
down level.
1Q,gi£
yolta.9.~
2.£Sl.~ncl.!!SI.
If
a
user
incorporates
a
technology such
that voltage
sequencing
must
occur
within
a
given
period
of
time
(>350ms),
the following method can
possibly
be
used.
Assume
that,
for
substrate
biasing
purposes,
Vn=-5.0V and Vh=8.5V; if Vn
1S
more positive than
-3.SV, Vh
must
not
remain above +S.OV for more
than
500ms.
Although
no
true
sequencing
occurs,
after approximately
350ms the power supply circuitry
checks
to
see
that
the
voltages
are
at
an
operational level, if not, the supply
shuts
down:
oth~~rwise
the
sequencing
is
met
and
the
technology is protected.