Figure 4-3. Transmit operation timing diagram
WR
WR
CD
I.A.
CD
I.A.
\
______
-Jlr----T-ra-n-sm-l-·t-o-p--~·
' - - - T Xo
----i.~1
---.. TL
~
Key:
) 1
(
(
- - . . TL
1 - - -
CD
Post device end interrupt (condition code 3)
LA.
Interrupt accept
WR
Write command accepted
Baud rate
TXO (milliseconds)
IL
(milliseconds)
9600
.936
.208
4800
1.87
.416
2400
3.74
.832
1200
7.49
1.66
600
14.98
3.33
300
29.96
6.66
200
44.94
10.0
150
59.9
13.3
110
81.9
18.2
100
89.88
20.0
75
119.08
26.6
50
179.76
40.0
TXO and T L are ±O.l %
I
4-14
GA34-0033
CD
(
~
,
;
/
Transmit op
I
..
c