Oki ML1120 Technical Reference Manual page 177

Hide thumbs Also See for ML1120:
Table of Contents

Advertisement

Sets SP bar width on the basis of parameter m, setting by
parameter S (MSB valid).
S
ADJUSTMENT VALUE FOR THE STANDARD
WIDTH OF SP BAR (1/360 IN UNIT)
FDH
-3
FEH
-2
FFH
-1
00H
0 (default)
01H
+1
02H
+2
03H
+3
For settings other than above, the value is set to 0.
Sets height (1/180 in unit) of black bar by parameter v1
and v2.
Black bar height = v1 + v2 x 256
0(00H) <= v1 <= 255(FFH)
0(00H) <= v2 <= 255(FFH)
The maximum setting value for height is 2 in. This can be
set in units of 15/180 in as follows:
SETTING RANGE
1 <= v1.v2 <= 15
16 <= v1.v2 <= 30
31 <= v1.v2 <= 45
46 <= v1.v2 <= 60
61 <= v1.v2 <= 75
76 <= v1.v2 <= 90
91 <= v1.v2 <= 105
106 <= v1.v2 <= 120
121 <= v1.v2 <= 135
Technical Reference Guide – Command descriptions > 177
SET
SETTING RANGE
VALUE
(IN)
15/180
196 <= v1.v2 <= 210
30/180
211 <= v1.v2 <= 225
45/180
226 <= v1.v2 <= 240
60/180
241 <= v1.v2 <= 255
75/180
256 <= v1.v2 <= 270
90/180
271 <= v1.v2 <= 285
105/180
286 <= v1.v2 <= 300
120/180
301 <= v1.v2 <= 315
135/180
316 <= v1.v2 <= 330
SET
VALUE
(IN)
210/180
225/180
240/180
255/180
270/180
285/180
300/180
315/180
330/180