Main Functions

1.11 Other Functions

1.11.1 Hot-Start Function
In order to prevent the cold air blast that normally comes when heating operation is started, the
temperature of the indoor heat exchanger is detected, and either the airflow is stopped or is
made very weak thereby carrying out comfortable heating of the room.
The cold air blast is also prevented using a similar control when the defrosting operation is
started or when the thermostat is turned ON.
1.11.2 Signal Receiving Sign
When the indoor unit receives a signal from the remote controller, the unit emits a signal
receiving sound.
1.11.3 Indoor Unit ON/OFF Button
An ON/OFF button is provided on the display of the unit.
<Forced cooling operation>
Forced cooling operation can be started by pressing the ON/OFF button for 5 to 9 seconds
while the unit is not operating.
Refer to page
Note:
When the ON/OFF button is pressed for 10 seconds or more, the forced cooling operation is
stopped.
1.11.4 Titanium Apatite Photocatalytic Air-Purifying Filter
This filter combines the Air-Purifying Filter and Titanium Apatite Photocatalytic Deodorizing
Filter as a single highly effective filter. The filter traps microscopic particles, decomposes odors
and even deactivates bacteria and viruses. It lasts for 3 years without replacement if washed
about once every 6 months.
1.11.5 Auto-restart Function
If a power failure (including one for just a moment) occurs during the operation, the operation
restarts automatically when the power is restored in the same condition as before the power
failure.
Note:
It takes 3 minutes to restart the operation because the 3-minute standby function is activated.
20
Press this button once to start operation. Press once again to stop it.
This button is useful when the remote controller is missing or the battery has run out.
The operation mode refers to the following table.
Mode
AUTO
for detail.
138
Temperature setting
25°C
ON/OFF button
ON/OFF
(R14568)
SiBE041102_A
Airflow rate
Automatic
Function and Control

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ftxn35kev1bRxn35kev1bRxn25kev1b

Table of Contents