Outdoor Unit
2.2

Removal of Outdoor Fan / Fan Motor

Procedure
Step
1. Remove the outdoor fan.
1
Remove the nut of the
outdoor fan.
Remove the outdoor
2
fan.
2. Remove the fan motor.
Disconnect the
1
connector [S70] and
release the fan motor
lead wire from the hook.
Release the fan motor
2
lead wire from the 3
hooks.
120
Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Mark
Outdoor fan
Nut
[S70]
D-cut
Shaft
(R14490)
Fan motor
Hook
lead wire
(R14491)
(R14492)
SiBE041102_A
Points
Preparation
Remove the panels
according to the "Removal
of Outer Panels".
Nut size: M6
10 mm
(R12236)
When reassembling, align
mark of the outdoor fan
with D-cut section of the
motor shaft.
[S70]: fan motor
When reassembling, set the
fan motor lead wire into the
hook.
When reassembling set the
fan motor lead wire into the
3 hooks.