SiBE041102_A
Step
3
Disconnect the
connector [S27] from
the display PCB.
The figure shows the
4
component parts of the
display PCB.
4. Remove the control PCB.
Lift the shield plate (1)
1
and unfasten the 2
hooks.
Slide the shield plate
2
(1) and remove it.
3
Release the harnesses
from the hooks.
Removal Procedure
Procedure
ON/OFF button
(Forced cooling operation
ON/OFF button)
TIMER lamp
Hook
[S27]: for control PCB
[S27]
Operation lamp
Signal receiver
(R14604)
Shield plate (1)
(R12061)
(R12062)
Indoor Unit
Points
109