Daikin FTXN25KEV1B Service Manual page 115

Inverter pair wall mounted type k-series
Hide thumbs Also See for FTXN25KEV1B:
Table of Contents

Advertisement

SiBE041102_A
Step
3. Remove the vertical blade
ASSY.
1
Unfasten the right and
left hooks of the fan
guard with pliers.
2
Unfasten the 4 hooks at
the bottom. Remove the
fan guard.
Unfasten the hooks at
3
the upper 2 positions.
Removal Procedure
Procedure
Hook
Fan guard
Hook
Vertical blade ASSY
Narrow the edges of the
Hook
hook to unfasten it.
(R14608)
Repeat the same procedure
to remove the fan guard on
the other side.
Hook
(R11647)
The right fan guard has
sealing materials on the
right side.
(R14611)
A vertical blade ASSY has 6
fins. It is impossible to
replace only one fin.
The vertical blade ASSY is
not marked for difference
between right and left.
(R8020)
(R8021)
Indoor Unit
Points
Hook
(R11646)
105