Main Functions
1.3
Airflow Direction Control
Power-Airflow
The large flap sends a large volume of air downwards to the floor. The flap provides an optimum
control in cooling, dry, and heating mode.
Flap
Cooling / Dry Mode
During cooling or dry mode, the flap retracts into the indoor unit. Then, cool air can be blown far
and distributed all over the room.
Heating Mode
During heating mode, the large flap directs airflow downwards to spread the warm air to the
entire room.
Wide-Angle
The louvers, made of elastic synthetic resin, provide a wide range of airflow that guarantees a
comfortable air distribution.
Louvers
Auto-Swing
The following table explains the auto swing process for cooling, dry, fan, and heating:
COMFORT
The vertical swing flap is controlled not to blow the air directly on the person in the room.
AIRFLOW
Operation
12
Vertical Swing (up and down)
Cooling / Dry / Fan
5˚
45˚
(R11256)
Cooling
0˚
(R11259)
Heating
15˚
45˚
(R11257)
Heating
50˚
(R11258)
SiBE041102_A
Function and Control