Daikin FTXN25KEV1B Service Manual page 131

Inverter pair wall mounted type k-series
Hide thumbs Also See for FTXN25KEV1B:
Table of Contents

Advertisement

SiBE041102_A
Step
3
Remove the screw and
remove the fan motor
fixing frame.
Release the fan motor
4
lead wire from the
hooks.
5
Remove the 3 screws
and remove the fan
motor.
Removal Procedure
Procedure
Fan motor fixing frame
Clamp
Fan motor
When reassembling, put the
fan motor lead wire through
the back of the fan motor so
as not to be entangled with
the outdoor fan.
Lead wire
(R14493)
When reassembling, set the
clamped position under the
lower hook of the fan motor
fixing flame.
(R14494)
(R14495)
Outdoor Unit
Points
Outdoor fan
(R3249)
121

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ftxn35kev1bRxn35kev1bRxn25kev1b

Table of Contents