Download Print this page

Starter Switch - Shindaiwa DGW400DM-C Owner's Manual

Sound attenuated diesel engine powered welder/generator
Hide thumbs Also See for DGW400DM-C:

Advertisement

SLOW
3-P
Restarting the engine after running out of fuel.
This equipment is equipped with an automatic air bleed feature that allows easily restarting the
engine after running out of fuel. If this machine runs out of fuel, use the following procedure for
re-starting.
1. Turn the start switch to the STOP position.
2. Refill the fuel tank.
3. Turn the Slow-Down switch to ON.
4. Turn the start switch to the START position and engage the starter motor for approximately
10 seconds until the engine starts.
5. Release the starter switch once the engine has started.
6. The engine will run erratically until all the air has been bled out. Wait for approximately 1
minute before adding load to allow the engine speed to become stable.
<Caution>
Do not turn the Slow-Down switch to OFF or connect loads until the air is completely
extracted. The air is completely extracted when engine speed becomes stable.
9-2 Stopping
1. Open (place in the OFF position) the single phase and three phase breakers (1-P and 3-P).
2. Turn the Slow-Down switch to ON.
3. Let the engine idle (cool down) for about 5 minutes.
4. Turn the start switch to the STOP position.
5. After the engine has stopped, shut the fuel shut-off valve.

STARTER SWITCH

SWITCH
1-P
18

Advertisement

loading