Download Print this page

Shindaiwa DGW400DM-C Owner's Manual page 23

Sound attenuated diesel engine powered welder/generator
Hide thumbs Also See for DGW400DM-C:

Advertisement

(2) Semi-Automatic Wire Feeder
1. Turn the CV/CC selector switch to CV.
2. Turn the output selector switch to Eco, Single or Dual, according to the desired mode of
operation.
3. Adjust voltage using the Current Adjust Dial A. Refer to the following table.
Eco
1 Person
Single
Use
Dual
2 Persons
Use
These values are approximations only. Factors such as the length of the welding cables and the
ambient temperature will affect the actual value.
When the remote control is used, these values may also vary.
11. Generator Operation
11-1 Ratings
Rated Frequency (Hz)
Rated Speed (rpm )
Phase
Rated Voltage (V)
Power Factor
Rated Output (kVA)
Rating
3-Phase 480V Output Receptacle
Maximum output from this receptacle is 15KVA (12 kW), 18 amps, at 480 v
Welding Voltage (V) / Amperage (A) at the dial position
Position
MIN
V
18
A
40
V
18
A
60
V
18
A
60
3-PHASE 480V RECEPTACLE
1
2
3
18
19
20
50
80
110
18
20
24
60
90
190
18
20
24
60
100
190
60
3600
1-Phase
1-Phase
120
240
1.0
1.0
2.2
Continuous
22
4
5
MAX
24
25
200
220
220
31
34
270
350
390
24
24
210
210
210
3-Phase
480
0.8
4.3
15
25
36
24

Advertisement

loading