4. After draining the water, reinstall the water drain plug.
5. Refill the coolant system with coolant/water to the upper edge of the radiator inlet.
6. Reinstall the radiator cap.
7. Reinstall the top plate.
14. Long-Term Storage
Danger: Electric Shock
Before performing any equipment check or maintenance, stop the engine and remove the engine
key. The person performing the maintenance should always keep the key.
Caution: Injuries
Before performing any equipment check or maintenance, stop the engine and remove the engine
key. The person performing the maintenance should always keep the key.
If the welder/ generator will not be used for more than two months, perform the following maintenance and
storage procedures.
1. Remove the battery.
2. Change the engine oil.
3. Drain all fuel from the fuel tank and the fuel strainer.
4. Cover the welder/generator and keep it in a clean dry location.
5. Recharge the battery once a month.
15. Troubleshooting
Danger: Electric Shock
Before performing any equipment check or maintenance, stop the engine and remove the engine
key. The person performing the maintenance should always keep the key.
Caution: Injuries
Before performing any equipment check or maintenance, stop the engine and remove the engine
key. The person performing the maintenance should always keep the key.
Caution: Fire, Burns
Before performing any equipment check or maintenance, stop the engine and remove the engine
key. The person performing the maintenance should always keep the key.
Temperatures around the engine, muffler, and exhaust can get extremely high. Allow these
areas to cool down before performing any maintenance checks.
Radiator Cap
Top Plate
30
Radiator Fill