6. Reassemble
7. Open the fuel shut off valve and check for leaks.
Fuel Shutoff Valve
5. Drain Water from Fuel Tank
Frequency
Drain Water
Procedure
1. Unscrew the fuel drain plug.
<Caution>
The contents of the fuel tank will begin to drain as soon as the fuel drain plug is loosened.
Ensure there is adequate means to contain the volume of liquid that is being drained.
2. After completely draining the water, reinstall the drain plug.
3. Refill the fuel tank.
6. Changing Coolant/Water
Frequency
Replace
Procedure
1. Remove the top plate.
2. Remove the radiator cap.
3. Loosen the water drain plug.
<Caution>
The contents of the coolant system will begin to drain as soon as the water drain plug is
loosened. Ensure there is adequate means to contain the volume of liquid that is being drained.
Total capacity of the coolant system including the sub tank (1/2 quart) is 4 quarts.
Open
Every 200 hours
Fuel Drain Plug
Every 2 years or 2000 hours
Close
Retainer Ring
29
Coolant Drain Plug