3. Clean/Change Air Filter Element
Frequency
Clean
Replace
<Caution>
Clean more frequently, if it is used in dusty environment.
Procedure
1. Loosen the wing bolt on the air cleaner cover and remove the air filter element.
2. Clean or replace the air filter element.
3. Reinstall the air filter element in reverse order (Kubota Part No. 15471-11083).
4. Clean/Change Fuel Strainer
Frequency
Clean
Replace
Procedure
1. Shut the fuel shut off valve.
2. Loosen the fuel filter retaining ring by turning it counterclockwise.
3. Remove the fuel filter bowl and the filter element.
4. Clean the fuel filter bowl.
5. Clean or replace the fuel filter element as required (Kubota Part No. 15521-43161).
st
1
at 50 hours and Every 100 hours
Thereafter
Every 400 hours
Air Cleaner
Wing Bolt
st
1
at 50 hours and Every 100 hours Thereafter
Every 400 hours
Air Cleaner Element
Wing Bolt