Leveling Leg Adjustment - Regency L390E Owners & Installation Manual

Gas insert
Hide thumbs Also See for L390E:
Table of Contents

Advertisement

INSTALLATION

LEVELING LEG ADJUSTMENT

The L390E / HZI390E inserts are equipped with 4 levelling legs that are
accessible while the appliance is in its fi nal installation position. The unit
can be adjusted up to 2" (51mm). The faceplate must not be installed to
do this adjustment, if installed, remove faceplate.
Remove left and right side fi ller pieces.The rear levelling bolts are located
in the back corners of the fi rebox and can be adjusted using a 7/16"
wrench. Rotate the bolts clockwise to raise the rear of the fi rebox.
The front levelling bolts are adjusted before installing the faceplate.
Located on the left on right of the outer shell, they can also be adjusted
using a 7/16" deep socket with extension.
When the appliance is in position, adjust the bolts to level the appliance,
making sure that the appliance is also level and is sitting on all 4 bolts to
prevent rocking.
Leveling Legs Rear
Leveling Legs Front
14
L390E / HZI390E Direct Vent Gas Insert