OPERATING INSTRUCTIONS

OPERATING
INSTRUCTIONS
Before operating this appliance, proceed through
the following check list.
1) Read and understand these Instructions before
operating this appliance.
2) Check to see that all wiring is correct and en-
closed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the glass door is in place. Never oper-
ate the appliance with the door glass removed.
5) Verify that all venting and the cap is unobstructed.
6) Verify log /glass crystal placement. If the pilot
cannot be seen when lighting the unit - the logs
/ crystals, or the embers have been incorrectly
positioned.
7) The unit should never be turned off and on again
without a minimum of a 60 second wait.
8) When lighting the appliance, the inside of the
glass may fog up. This will burn off after a few
minutes of operation.
DO NOT BURN THE APPLIANCE WITH
THE GLASS DOOR REMOVED.
38
38
LIGHTING
PROCEDURE
IMPORTANT
To ignite or reignite the pilot, you
must fi rst remove the glass door.
1) Press and release on ON/OFF button once
on the remote control or ON/OFF switch.
2) After approximately 4 seconds the spark
ignition system will spark for 60 seconds to
light the main burner.
3) The unit will turn on.
Note: The fi rst try for ignition will last approxi-
mately 60 seconds. If there is no fl ame ignition
(rectifi cation) the board will stop sparking for
approximately 35 seconds. After wait time ,
the board will start second try for ignition by
sparking for approximately 60 seconds . If
there is still no positive ignition the board will
go into lock out.
The system will need to be reset as follows:
a) Turn the system off using ON/OFF switch or
press ON/OFF button - if using optional remote.
b) After approximately 2 seconds turn on ON/
OFF switch or press ON/OFF button if using
optional remote.
c) Repeat step 2.
SHUTDOWN
PROCEDURE
1) Turn the wall mounted switch or remote to the
"OFF" position.
2) Press "OFF" on the remote control.
3) Turn the gas control knob to the "OFF" position
to turn off the pilot.

FIRST FIRE

The fi rst fi re in your stove is part of the paint curing
process. To ensure that the paint is properly cured,
it is recommended that you burn your fi replace for
at least four (4) hours the fi rst time you use it with
the fan on. When fi rst operated, the unit will release
an odour caused by the curing of the paint, the
burning off of any oils remaining from manufacturing.
Smoke detectors in the house may go off at this
time. Open a few windows to ventilate the room for
a couple of hours.
The glass panel may require cleaning after the unit
has cooled down.
DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS HOT.
Note: When the glass is cold and the appliance
is lit, it may cause condensation and fog
the glass. This condensation is normal
and will disappear in a few minutes as
the glass heats up.
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
During the fi rst few fi res, a white fi lm
may develop on the glass front as part
of the curing process. The glass should
be cleaned or the fi lm will bake on and
become very diffi cult to remove. Use a
non-abrasive cleaner and NEVER clean
the glass while it is hot.
AUTOMATIC
CONVECTION FAN
OPERATION
The fan operates automatically, turn the knob on
the side of the faceplate to adjust to the desired
speed. The fan will turn on as the stove comes up
to operating temperature. After the unit has been
turned off and the unit cooled to below a useful
heat output range the fan will shut off automatically.