INSTALLATION
Note: Ensure that the two wires that go to the fan control box go through
the grommet installed in Step 6.
Ground
Black
Neutral
Green
Live
Ground
120V AC
60 Hz
ON
OFF
Black
Black
Fan Speed
Controller
8) Secure the green ground wire to the ground lug on the unit, just left of the
thermodisc location - see Diagram 8 below.
9) Bundle wires together and secure to the unit with a wire clip, one at the
base of the side access and one on the back of the fan access panel.
Diagram 9a
20
Fan
Red
Fan Thermodisc
(normally open)
Black
Red
Ground wire
Thermodisc
Diagram 8
Side Access
Clip
Back panel
Clip
Diagram 9b
10) Install fan control box through the backing plate of the faceplate (see
installation instructions in this manual to install on unit. Secure the knob
in the front of the faceplate with a washer and a bolt.
11) Install the knob cover over the knob.
Diagram 11
12) Reverse Step 1.
13) Attach power cord to side of faceplate with grommet.
WARNING
Electrical Grounding Instructions
This appliance is equipped with a three-prong (grounding) plug
for your protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle. Do not
cut or remove the grounding prong from this plug.
Diagram 10