installation

LEVELING LEG AdjuSTmENT

The L540EB / HZI540EB inserts are equipped with 4 levelling legs that
are accessible while the appliance is in its final installation position.
The unit can be adjusted up to 5/8" (16mm). The faceplate must not be
installed to do this adjustment, if installed, remove faceplate.
Remove left and right inner panels by sliding them forward. The rear
levelling bolts are located in the back corners of the firebox and can be
adjusted using a 7/16" wrench. Rotate the bolts clockwise to raise the rear
of the firebox.
The front levelling bolts are adjusted before installing the faceplate.
Located on the left on right of the outer shell, they can also be adjusted
using a 7/16" deep socket with extension.
When the appliance is in position, adjust the bolts to level the appliance,
making sure that the appliance is also level and is sitting on all 4 bolts to
prevent rocking.