Levelling Leg Adjustment - Regency L390E Owner's Manual

Gas insert
Hide thumbs Also See for L390E:
Table of Contents

Advertisement

INSTALLATION

LEVELLING LEG ADJUSTMENT

The L390E / HZI390E inserts are equipped with 4 levelling legs that are accessible while the appliance is in its fi nal installation position. The unit can be
adjusted up to 2" (51mm). The faceplate must not be installed to do this adjustment, if installed, remove faceplate.
Remove left and right side fi ller pieces.The rear levelling bolts are located in the back corners of the fi rebox and can be adjusted using a 7/16" wrench.
Rotate the bolts clockwise to raise the rear of the fi rebox.
The front levelling bolts are adjusted before installing the faceplate. Located on the left on right of the outer shell, they can also be adjusted using a 7/16"
deep socket with extension.
When the appliance is in position, adjust the bolts to level the appliance, making sure that the appliance is also level and is sitting on all 4 bolts to prevent
rocking.
Leveling Legs Rear
Leveling Legs Front
15
L390E-2 / HZI390E-2 Direct Vent Gas Insert

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hzi390e

Table of Contents