Lift Control Manifold

RIGHT
FRONT
2
3
4
5
6
1. Lift control manifold
2. Filter mount bracket
3. Filter head
Removal (Fig. 88)
NOTE: The ports on the manifold are marked for easy
identification of components. Example: P is the supply
connection port (see Hydraulic Schematic in Chapter 9
-- Foldout Drawings to identify the function of the hydrau-
lic lines and cartridge valves at each port).
1. Park machine on a level surface, lower cutting units,
stop engine, apply parking brake and remove key from
the ignition switch.
IMPORTANT: To prevent unexpected cutting unit
lowering, make sure that cutting units are fully low-
ered before loosening hydraulic lines from lift man-
ifold.
Hydraulic System
7
1
Figure 88
4. Hydraulic oil filter
5. Valve mount bracket
2. Read the General Precautions for Removing and
Installing Hydraulic System Components at the begin-
ning of the Service and Repairs section of this chapter.
3. Unlatch and raise hood.
4. To prevent contamination of hydraulic system during
manifold removal, thoroughly clean exterior of manifold.
5. Label wire harness electrical connectors that attach
to manifold solenoid coils. Disconnect wire harness
electrical connectors from the solenoid valve coils.
Page 4 - - 118
8
6. Flange head screw (2 used)
7. Mow control manifold