Hour Meter
The hour meter is located on the outside of the console
arm.
1. Connect the positive (+) terminal of a 12 VDC source
to the positive (+) terminal of the hour meter.
2. Connect the negative (--) terminal of the voltage
source to the other terminal of the hour meter.
3. The hour meter should move a 1/10 of an hour in six
(6) minutes.
4. Disconnect voltage source from the hour meter.
Temperature Gauge
The temperature gauge on the control panel indicates
engine coolant temperature level during machine op-
eration (Fig. 22). The changing resistance of the engine
temperature sender signals the temperature gauge.
The temperature gauge should display the first green
segment when the ignition switch is turned to ON. The
first yellow segment on the gauge should display when
engine coolant temperature is approximately 212
o
(100
C).
When engine coolant temperature rises to approximate-
o
o
ly 221
F (105
C), the temperature gauge should display
the first red segment.
Electrical System
o
F
1
1. Console arm
2. Temperature gauge
Page 5 - - 20
Hobbs
QUARTZ
1
0 0 0 0
1
10
HOURS
+
BACK
Figure 21
3
Figure 22
3. High temp indicator