System Example For The Logamax Plus Gb162-65/80/100 With Low Loss Header And Rc35 Programming Unit, One Heating Circuit; Cylinder Primary Pump - Buderus Logamax plus GB162 Technical Manual

Gas condensing boiler output range from 2.7 kw to 100 kw
Hide thumbs Also See for Logamax plus GB162:
Table of Contents

Advertisement

6
System examples
6.4.5
System example for the Logamax plus GB162-65/80/100 with low loss header and RC35
programming unit, one heating circuit without mixer, two heating circuits with mixers and DHW
heating via a cylinder primary pump
FS
FA
2x0,6 2
BC10
MM10
MM10
WM10
2)
SV
VK
RK
Fig. 78 Circuit diagram for the system example (index of abbreviations
1)
Hydraulic balancing at the thermostatic valves/zone valves
recommended
2)
Pump and safety valve integrated in the pump connection
assembly (
fig. 46, page 53)
3)
Differential pressure-dependent pump
The circuit diagram is only a schematic
illustration.
Information regarding all system examples
page 52 ff.
Brief description
• RC35 programming unit, combined with a WM10 low
loss header module and two MM10 mixer modules, one
heating circuit without control and one with mixer, plus
cylinder primary and DHW circulation pump.
• Time-dependent actuation of the DHW circulation
pump and cylinder primary pump possible via the
RC35 programming unit.
• The RC35 programming unit can be installed either
inside the gas condensing boiler or in a reference
room.
• Optional DHW heating in parallel mode.
• Up to three heating circuits with mixer and one heating
circuit without mixer are feasible with the RC35
programming unit.
80
RC35
BUS
PZ
3x1,5 2
2x0,6 2
3x1,5 2
KR
FW
EK
MAG
3x1,5 2
3x1,5 2
2x0,6 2
4x1,5 2
SMF
2x0,6 2
2
4x1,5
2
2x0,6
2
3x1,5
THV
PS
FV2
KR
PH2
3)
PH1
SH2
(HS...)
RH
VH
FK
WH
page 52)
• An individual time channel is available for DHW.
Special design information
• For the Logamax plus GB162-65/80/100 two modules
may also be installed inside the appliance.
• In combination with a low loss header, the integral
pump in the pump connection assembly of the GB162
must be controlled subject to output (setting 0 at the
RC35 programming unit).
• For the Logamax plus GB162-65/80/100, order the
pump assembly as an accessory.
6 720 645 821 (2010/09) – Logamax plus GB162
1)
HK1
1)
ZV (THV)
HK2
HK3
TWH
TWH
FV3
KR
KR
3)
3)
PH3
SH3
(HSM...)
(HSM...)
(HKV 4/...)
6 720 642 463-62.1il
1)
ZV (THV)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents