435
1277
720
Fig. 124 Plastic components of the standard DO set
(dim. in mm)
1
Roof outlet DN80/125
2
Rafter clip, zinc-plated steel
3
Fascia, in 3 parts
4
Pipe collar (accessory for tying in a vapour barrier)
The following are also part of the standard delivery:
- One tube Centrocerin
- System certification label
≥ 1
< 1,5
Fig. 125 Minimum clearances towards windows with the
DO set (dim. in m) (examples in accordance
with the Muster-Feuerungsverordnung
[Germany]; regulations
H
No special clearance required
6 720 645 821 (2010/09) – Logamax plus GB162
2
1
3
4
6 720 642 463-82.1il
H
≥ 1
> 1,5
7 747 009 801-79.1il
page 132)
Flue systems for balanced flue operation
A
153
(0°–15°)
395
Fig. 126 Universal roof tile and adhesive flat roof flange
as additional equipment for the standard DO
set (must be ordered separately); (dim. in mm)
A
For flat roof
B
For pitched roof
7
Adhesive flat roof flange
8
Universal roof tile
Tiles for alternative roof slopes available on
request.
B
7
25°– 45°
500
6 720 641 280-63.1il
10
8
139