Heat Exchanger Recognition Set For Gas Condensing Boilers - Buderus Logamax plus GB162 Technical Manual

Gas condensing boiler output range from 2.7 kw to 100 kw
Hide thumbs Also See for Logamax plus GB162:
Table of Contents

Advertisement

8.5

Heat exchanger recognition set for gas condensing boilers

(WMS 1)
RH
220
2)
AS HKV DN25
Fig. 89 Dimensions of heat exchanger recognition with
integral heating circuit pump (dim. in mm)
FK
Flow temperature sensor
FE
Drain & fill valve
MAG
Diaphragm expansion vessel
RH
Non-return valve
RK
Boiler return
VH
Heating circuit flow
VK
Boiler flow
1)
Install the MAG on site
2)
Adaptor from G1¼ to R1 (order as an accessory)
Use in underfloor heating systems with pipes permeable
to oxygen or in systems where antifreeze is to be used in
specific heating circuits.
The heating circuit downstream of the heat exchanger is
protected by a safety set.
Size the MAG on site in accordance with DIN 4807 and
DIN-EN 12828.
Maximum transfer capacity of the system
separation for heating circuits with DT = 10 K and
200 mbar pressure drop:
HS 25/4 E plus
8.5 kW
HS 25/6 E plus
15 kW
HSM15 E plus
7 kW
HSM 20 E plus
15 kW
HSM 25 E plus
15 kW
6 720 645 821 (2010/09) – Logamax plus GB162
290
VH
RH
HS 20/25
400
VH
FK
MAG
FE
130
VK
RK
6 720 641 280-38.1il
Δp [mbar]
1000
500
100
10
1)
1
100
Fig. 90 Pressure drop curve of the heat exchanger
Δp
Pressure drop
m
Mass flow
The pipe assembly for system separation comprises a
copper-soldered stainless steel heat exchanger, a 2.5 bar
safety valve, a pressure gauge, a drain & fill valve and a
G¾ connection for the on-site diaphragm expansion
vessel.
The insulation of the low loss header across is used as
thermal insulation.
Installation
500
1000
3000
m [kg/h]
6 720 641 280-41.1il
8
103