Toshiba e-STUDIO230L Service Handbook page 378

Hide thumbs Also See for e-STUDIO230L:
Table of Contents

Advertisement

(2)
Step 2
Case C:
Loosen the fixing screw and hand screw of the right side hinge and then turn the adjustment
screw counterclockwise.
Case D:
Loosen the fixing screw and hand screw of the right side hinge and then turn the adjustment
screw clockwise.
Note:
Note:
When adjusting, refer to the hinge position (scribed line) and be sure not to move it from the
hinge position ±0.5 mm or further. Otherwise, image failures such as a jitter may occur.
C
(3)
Step 3
Case E:
Adjust the reverse aligning adjustment position to the rear side "-" of the original (
"3.10.6 Adjustment of aligning at reversing").
Case F:
Adjust the reverse aligning adjustment position to the rear side "+" of the original (
"3.10.6 Adjustment of aligning at reversing").
e-STUDIO200L/202L/203L/230/232/233/280/282/283
ADJUSTMENT
D
Paper
Original
Fig. 3-66
E
F
Paper
Original
Fig. 3-68
© 2004 - 2007 TOSHIBA TEC CORPORATION All rights reserved
3 - 60
Fixing screw
Adjustment screw
Hand screw
RADF
↓Front side
Fig. 3-67
P.3-63
P.3-63

Hide quick links: