Setting mode (08) <e-STUDIO202L/203L/232/233/282/283>
Classifi-
Code
cation
440
Fuser
Pre-running time for first
printing
(Plain paper)
441
Fuser
Pre-running time for first
printing
(Thick paper 1)
448
Fuser
Fuser roller temperature in
Energy Saving Mode
(Side thermistor)
449
Paper
Incorrect paper size jam
feeding
detection switching
450
Fuser
Fuser roller temperature
during printing
(Side thermistor/Plain
paper)
451
Fuser
Fuser roller temperature
during printing
(Side thermistor/Thick
paper 1)
e-STUDIO200L/202L/203L/230/232/233/280/282/283
ERROR CODE AND SELF-DIAGNOSTIC MODE
Func-
Items
tion
ALL
ALL
ALL
ALL
ALL
ALL
2 - 178
07/11
Default
<Accept-
RAM
able
value>
0
M
0: Invalid 1: 1 sec.
<0-15>
2: 2 sec. 3: 3 sec.
4: 4 sec. 5: 5 sec.
6: 6 sec. 7: 7 sec.
8: 8 sec. 9: 9 sec.
10: 10 sec.
11: 12 sec.
12: 14 sec.
13: 16 sec.
14: 18 sec.
15: 20 sec.
0
M
0: Invalid 1: 1 sec.
<0-15>
2: 2 sec. 3: 3 sec.
4: 4 sec. 5: 5 sec.
6: 6 sec. 7: 7 sec.
8: 8 sec. 9: 9 sec.
10: 10 sec.
11: 12 sec.
12: 14 sec.
13: 16 sec.
14: 18 sec.
15: 20 sec.
0
M
0: OFF
<0-13>
2: 50°C
4: 70°C
6: 90°C
8: 110°C 9: 120°C
10: 130°C
11: 140°C
12: 150°C
13: 160°C
0
M
0: Enabled
<0-1>
1: Disabled
8
M
0: 140°C 1: 145°C
<0-14>
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
8
M
0: 140°C 1: 145°C
<0-14>
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
© 2004 - 2007 TOSHIBA TEC CORPORATION All rights reserved
Proce-
Contents
dure
1
1
1: 40°C
1
3: 60°C
5: 80°C
7: 100°C
1
1
1