Troubleshooting
pnt0-19
IRQ found for PCnet hardware does not match space.c (or pnt.conf)!
Explanation: This is a warning message referring to the interrupt request (IRQ) that
the SunSoft Solaris driver found in the system.
Action: Ignore this message if you are sure that this is what you want to do.
Otherwise, run the NETCONFIG program to match the hardware settings
pnt0-20
add_intr_handler failed! Unknown interrupt type.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was
found, conflicts with other devices in the server.
Action:
pnt0-21
add_intr_handler failed! Out of range interrupt number.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was
found, conflicts with other devices in the server.
Action:
add_intr_handler failed! Out of range IPL.
pnt0-22
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was
found, conflicts with other devices in the server.
Action: Modify your hardware settings. Run the NETCONFIG program to search for
another Ethernet controller.
add_intr_handler failed! Vector already occupied.
pnt0-23
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was
found, conflicts with other devices in the server.
Action: Modify your hardware settings.
pnt0-24
add_intr_handler failed! Vector already shared at different IPL.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was
found, conflicts with other devices in the server.
Action:
pnt0-26
The DMA number is not necessary for PCI device.
Explanation: The IBM Netfinity 10/100 Fault Tolerant Adapter does not require a
DMA setting.
Action: Edit the SPACE.C file to delete the DMA parameter.
pnt0-29
The IRQ number is already in use.
Explanation: The specified I/O address is already in use.
Action: Run the NETCONFIG program to modify your hardware settings.
154
IBM® Netfinity® 4500R User's Reference
Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
Table 25. UNIX LLI driver messages for the Ethernet controller