POST message
289
An error occurred during POST memory tests and a failing DIMM was disabled.
Note:
Action:
If the problem persists, call for service.
301
An error occurred during the keyboard and keyboard controller test. These error
303
messages also might be accompanied by continuous beeping.
Action:
Running the diagnostic tests can isolate the server component that failed, but you must
have your system serviced. If the error message remains, call for service.
Note:
602
Invalid diskette boot record
Action:
If the problem persists, call for service.
604
An error occurred during a diskette drive test.
Action:
662
A diskette drive configuration error occurred.
Action:
If the problem persists, call for service.
962
A parallel port configuration error occurred.
Action:
If the problem persists, call for service.
Table 15. POST error messages
116
IBM® Netfinity® 4500R User's Reference
You can use the server with decreased memory.
1. If you just installed memory, verify that the new memory is correct for
your server. Also verify that the memory is installed and seated
correctly. Start the Configuration/Setup Utility program and select
Memory Settings from the Advanced Setup menu to enable the
DIMM.
2. If the problem remains, replace the failing DIMM.
Ensure that:
1. Nothing is resting on the keyboard and pressing a key.
2. No key is stuck.
3. The keyboard cable is connected correctly to the keyboard and to the
correct connector on the server.
If you just connected a new mouse or other pointing device, turn off the server
and disconnect that device. Wait at least 5 seconds; then, turn on the server. If
the error message goes away, replace the device.
1. Replace the diskette.
2. If the problem persists, make sure that the diskette drive cables are
correctly and securely connected.
3. If the problem remains, replace the diskette drive.
1. Verify that the Configuration/Setup Utility program correctly reflects
the type of diskette drive that you have installed.
2. Run the diagnostic tests. If the diagnostic tests fail, call for service.
If you removed a diskette drive, make sure that the diskette drive setting is
correct in the Configuration/Setup Utility program. If the setting is not
correct, change it.
If you changed a hardware option, make sure that the parallel port setting
is correct in the Configuration/Setup Utility program. If the setting is not
correct, change it.